Hybrid immersion cooling uses boiling coolant drops to cut AI chip hotspots 17°C

A research team at the University of Waterloo is developing a hybrid immersion cooling approach aimed at reducing short-duration chip hotspots in AI data centers by combining a water immersion bath with targeted drops of a lower-boiling-point electronics coolant.

The concept splits the job between two fluids: deionized water provides baseline immersion cooling, while small drops of a more expensive coolant are used for spot cooling when localized temperatures spike. “It’s a division of labour,” said Dr. Sushanta Mitra, a professor of mechanical and mechatronics engineering at the University of Waterloo. “Water is excellent at handling steady, everyday heat and the drops take care of sudden spikes.”

Hotspots are a familiar problem in high-power devices: depending on workload, small regions on a chip can heat up quickly, which can lead to throttling, accelerated aging, and reliability risk. The Waterloo work targets that transient behavior, where bulk coolant flow may not respond quickly enough to a rapid temperature rise.

The team, which includes Dr. Tian-Yu Zhang (postdoctoral researcher) and Arnav Banerjee (PhD student), selected an electronics coolant with a lower boiling point than water. The coolant is also heavier than water, which the researchers say helps it remain separate rather than mixing into the immersion bath.

In lab testing, the researchers report that a single coolant drop boiled and reduced the temperature of a simulated chip hotspot—submerged in a water tank—by up to 17° C in 15 seconds, several times faster than conventional immersion cooling. Mitra attributed the effect to phase-change heat transfer and mixing: “Boiling soaks up a lot of heat and the rising bubbles stir the surrounding water so it carries heat away faster,” he said. “We get the punch of boiling, but only where and when it’s needed.”

To tune how the drops behave, the team used a liquid-liquid encapsulation method to wrap the coolant drops in a thin skin of silicone oil. They also added tiny heat-conducting ceramic particles to the coating to help control the boiling rate.

Two system-level implementations are being considered: coolant drops that circulate through the water and activate when they contact hotspots, or drops delivered directly to hotspots identified by sensors. If it can be engineered into a controllable, serviceable loop, the approach is a practical attempt to reserve expensive dielectric fluid for only the parts of the thermal problem that actually need phase-change performance.

The work was published online in the Journal of Colloid and Interface Science as “A hybrid immersion cooling assisted by liquid-liquid encapsulation: A game changer for thermal management of transient hotspots.”

Source: University of Waterloo

AFF — below-posts ()

Get Data Center Engineering News In Your Inbox:

By subscribing, you agree to our Privacy Policy and Terms of Use. You can unsubscribe at any time.

Sponsored: Infineon at OCP 2026: Exclusive Content Hub. Executive interviews, technical documents, reference designs, and live expert panel. Unlock the hub.
Yokogawa — tower ()

Popular Posts:

Screenshot
Solid-state transformer converts 13.8 kV AC to 800 VDC, Enphase says
Dewalt-31
The data center critical path runs through the slab, and DEWALT wants a robot on it
DCE-AAF-Promo-Banner-Sentence-Case-1200x675
Webinar: Optimizing data center sustainability and efficiency through smarter air filtration
Gates-ThermalCool-2100SS-Pump
Gates launches 4U ThermalCool 2100SS pump for rack CDUs, 200 L/min flow
Vertiv-PowerStation-3100
Vertiv PowerStation 3100 remote power panel scales to 1,200 A for AI racks

Share Your Data Center Engineering News

Do you have a new product announcement, webinar, whitepaper, or article topic? 

Chroma — tower

Get Data Center Engineering News In Your Inbox:

By subscribing, you agree to our Privacy Policy and Terms of Use. You can unsubscribe at any time.

AFF — leaderboard ()