Delta debuts 2.5 MW 800 VDC in-row liquid-to-liquid CDU at SC26

Delta Electronics used SC26 to detail new liquid and air-cooling hardware aimed at AI infrastructure, alongside thermal technologies designed for emerging 800 VDC and ±400 VDC power architectures. The lineup spans chip, board, rack, and row-level cooling, including a 2.5 MW in-row liquid-to-liquid coolant distribution unit (L2L CDU), a hot-swappable cold plate for stacked SSDs, and an embedded cold plate intended to cool up to 3,000 W components.

At the chip level, Delta described next-generation cooling technologies that include advanced thermal interface materials and micro-channel lid structures. At the board level, Delta introduced new cold plate designs that extend liquid cooling beyond compute into power, memory, and networking applications, including an “ultra-thin” Power Shelf Embedded Cold Plate with customizable manifold layouts and low-resistance multi-channel flow paths for space-constrained power systems.

Delta also showed a Vertical Power Delivery (VPD) Double-Sided Cooling Solution for Open Adapter Card (OAC) architectures. The company lists support for cooling up to 3,000 W of computing components and 500 W of power components within a 40 mm cold plate profile, with heat flux exceeding 170 W/cm². For memory and storage serviceability, Delta’s hot-swappable SSD cold plate uses a modular design for stacked SSDs.

On coolant distribution, Delta’s rack-level system includes a 4U in-rack CDU rated for up to 200 kW of cooling capacity. For row-level deployments, the company highlighted two designs: the Project Deschutes Open In-Row CDU, specified at up to 2 MW of cooling with a 3°C approach temperature, and a Google OCP Project Brazos rack-mounted liquid-to-air CDU rated for up to 60 kW per rack using a self-contained, closed-loop design.

Higher-voltage distribution can shift more heat into power conversion and delivery gear, so cooling designs that explicitly target 800 VDC and ±400 VDC architectures are worth watching. The practical question for operators is less about “from-grid-to-chip” messaging and more about how these CDUs, cold plates, and airflow systems integrate into real plant constraints: pump redundancy models, approach temperatures, pressure drops, service windows, and how those choices affect uptime in dense AI rows.

For 800 VDC deployments, Delta’s in-row 2.5 MW L2L CDU is equipped with three 800 VDC, 25 kW hot-swappable pumps in a 3+0 configuration, designed to support zero-downtime operation. Delta lists a flow rate up to 3,850 LPM and 60 psi at the operating point. On the air side, Delta described a next-generation fan wall with 450 mm EC blowers, brushless DC motors, biomimetic impellers, and waterproof protection. “Particularly our full stack chip-to-system liquid cooling solutions are expanding beyond compute platforms to next-generation networking, memory/storage, and power cooling applications,” said Martin Tsai, General Manager of Fans and Thermal Management Business Group, Delta Electronics.

Delta Electronics

Source: Delta Electronics (Americas)

Yokogawa — below-posts ()

Get Data Center Engineering News In Your Inbox:

By subscribing, you agree to our Privacy Policy and Terms of Use. You can unsubscribe at any time.

Sponsored: Infineon at OCP 2026: Exclusive Content Hub. Executive interviews, technical documents, reference designs, and live expert panel. Unlock the hub.
TDK — tower ()

Popular Posts:

Screenshot
Solid-state transformer converts 13.8 kV AC to 800 VDC, Enphase says
Dewalt-31
The data center critical path runs through the slab, and DEWALT wants a robot on it
DCE-AAF-Promo-Banner-Sentence-Case-1200x675
Webinar: Optimizing data center sustainability and efficiency through smarter air filtration
Gates-ThermalCool-2100SS-Pump
Gates launches 4U ThermalCool 2100SS pump for rack CDUs, 200 L/min flow
Vertiv-PowerStation-3100
Vertiv PowerStation 3100 remote power panel scales to 1,200 A for AI racks

Share Your Data Center Engineering News

Do you have a new product announcement, webinar, whitepaper, or article topic? 

Chroma — tower

Get Data Center Engineering News In Your Inbox:

By subscribing, you agree to our Privacy Policy and Terms of Use. You can unsubscribe at any time.

AFF — leaderboard ()