Chroma — leaderboard

Infineon’s H-DPAK integrates a 750 V CoolSiC half-bridge for HVDC AI server power supplies in a liquid-cooling-ready package

Infineon has introduced the H-DPAK, a new top-side-cooled package integrating a complete half-bridge built on its 750 V CoolSiC G2 SiC MOSFET technology. The primary application target on the data center side is HVDC AI server power supplies—specifically five-level Active Neutral Point Clamped (5L ANPC) topologies—alongside HVDC battery and capacitor backup units.

As AI server clusters have pushed rack power densities into the tens of kilowatts, HVDC power distribution at 380 V and higher has become the dominant architecture for efficiency-sensitive deployments. The power supply units feeding those buses run complex multilevel topologies like 5L ANPC precisely because they need high efficiency at high voltages without pushing switch voltage stress to the limit—750 V-rated SiC fits that window with margin.

The H-DPAK integrates the full half-bridge—high-side and low-side switches—in a single package, rather than placing discrete devices on the board. The split lead frame design with optimized drain pads reduces parasitic loop inductance for cleaner switching at the high dv/dt rates SiC enables, while improving heat spreading across the package. Top-side cooling orientation makes the device compatible with liquid cooling in dense power stages, where removing heat through the board is impractical at these power levels.

The 2.3 mm package height matches Infineon’s existing Q-DPAK and TOLT packages for drop-in board compatibility. The 750V CoolSiC G2 adds low gate charge, high dv/dt capability, and wide gate-bias tolerance—useful for designs where gate driver architecture flexibility matters.

Source: Infineon Technologies

Yokogawa — below-posts ()

Get Data Center Engineering News In Your Inbox:

By subscribing, you agree to our Privacy Policy and Terms of Use. You can unsubscribe at any time.

Sponsored: Infineon at OCP 2026: Exclusive Content Hub. Executive interviews, technical documents, reference designs, and live expert panel. Unlock the hub.
Chroma — tower

Popular Posts:

abb-infinitus copy
ABB launches 800 VDC source-to-rack DC power portfolio for AI data centers
schneider-electric-unveils-new-prefabricated-reference-desig
Schneider Electric RapidScale modular AI data center design targets NVIDIA Vera Rubin
Engineering AI Rack Power: Infineon Answers the Questions Asked at OCP, live expert panel with Carl Smith, Davide Chiola and Michael Williams
AI data center architecture evolution and key findings from OCP
Peak+_Truck_Photo_-_10-19-26
Peak+ demo truck shows adiabatic pre-cooling on air-cooled chillers
ds6000-on_white
Celestica launches DS6005 102.4Tbps CPO liquid-cooled AI switch

Share Your Data Center Engineering News

Do you have a new product announcement, webinar, whitepaper, or article topic? 

Yokogawa — tower ()

Get Data Center Engineering News In Your Inbox:

By subscribing, you agree to our Privacy Policy and Terms of Use. You can unsubscribe at any time.

Yokogawa — leaderboard ()