AEWIN debuts AMD EPYC 9006 servers with two-phase direct liquid cooling

AEWIN detailed two new AMD EPYC 9006-based AI servers, the 1U BG18-A10710 and 5U BG58-A20810, both built around an integrated two-phase direct liquid cooling (2P DLC) design aimed at higher compute density and tighter thermal control in AI and HPC deployments.

The 1U BG18-A10710 is built for high-density heterogeneous compute in a compact chassis. It supports a single AMD EPYC “Venice” SP7 CPU with up to 600 W TDP, two PCIe Gen6 SW FHFL accelerators, 16 DDR5 RDIMM or MRDIMM slots with memory speeds up to 12,800 MT/s, and eight E1.S Gen6 NVMe SSD bays. For management, it includes OCP DC-SCM2 system management via an ASPEED AST2700 BMC, and it’s configured with redundant 2,700 W 80 PLUS Titanium power supplies.

The 5U BG58-A20810 targets larger-scale parallel compute. It supports dual AMD EPYC 9006 SP8 server CPUs rated at 400 W TDP and “next-gen DDR5/MRDIMM” memory subsystems. On the accelerator side, AEWIN’s top configuration supports up to 16 PCIe Gen6 NVIDIA RTX Pro 6000 GPUs integrated with 2P DLC. AEWIN also lists an alternative configuration supporting up to eight air-cooled PCIe Gen6 accelerators.

Two-phase DLC is a very different thermal design problem than single-phase cold plates: AEWIN describes using a low-boiling-point coolant and a phase-change mechanism (liquid-to-vapor transition) to improve heat transfer and cut energy consumption. If it performs as intended in real deployments, the practical upside for operators is more headroom before fans, heat exchangers, and facility cooling become the limiting factor on GPU and CPU density.

AEWIN said it is ready to provide samples of the BG18-A10710 and BG58-A20810 for technical evaluation.

Source: AEWIN

Yokogawa — below-posts ()

Get Data Center Engineering News In Your Inbox:

By subscribing, you agree to our Privacy Policy and Terms of Use. You can unsubscribe at any time.

Sponsored: Infineon at OCP 2026: Exclusive Content Hub. Executive interviews, technical documents, reference designs, and live expert panel. Unlock the hub.
Chroma — tower

Popular Posts:

Screenshot
Solid-state transformer converts 13.8 kV AC to 800 VDC, Enphase says
data-center-cooling-tower-basin
Data center coatings and fireproofing: Earlier supplier collaboration could save build teams millions
image-10
Delta debuts 2.5 MW 800 VDC in-row liquid-to-liquid CDU at SC26
Mission-critical data center cooling webinar
Webinar: Gaskets for mission-critical data center power and cooling
Dewalt-31
The data center critical path runs through the slab, and DEWALT wants a robot on it

Share Your Data Center Engineering News

Do you have a new product announcement, webinar, whitepaper, or article topic? 

Yokogawa — tower ()

Get Data Center Engineering News In Your Inbox:

By subscribing, you agree to our Privacy Policy and Terms of Use. You can unsubscribe at any time.

AFF — leaderboard ()