CoolIT Systems launches coolant distribution unit delivering 1,500 kW cooling capacity for high-density data centers

CoolIT Systems has introduced the CHx1500, a liquid-to-liquid coolant distribution unit (CDU) engineered for high-performance data center applications, especially artificial intelligence (AI) and high-performance computing (HPC). With a cooling capacity of 1,500 kW, flow rates up to 1.2 liters per minute per kilowatt (LPM/kW) at a 5°C approach temperature difference (ATD), and secondary loop pumping pressure up to 44 psi, the CHx1500 offers significantly greater performance in a compact row-based form factor.

The CHx1500 has a footprint of 750 mm × 1200 mm, providing a cooling load density of approximately 1,516 kW/m². Compared to other major row-based CDUs available, the CHx1500 claims 27% to 148% higher cooling load capacity, 53% to 463% greater cooling density, and 26% to 75% higher pump pressure. According to CoolIT, the single rack-sized unit is fully serviceable from both front and back, includes hot-swappable critical components, and provides multiple redundancy levels.

Specifically targeting hyperscale data centers, the CHx1500’s cooling capacity is suited to support nine racks containing NVIDIA GB200 NVL72 servers. Engineered collaboratively with processor manufacturers and hyperscalers, the system features stainless steel piping, built-in 25-micron filters, premium wetted materials, and intelligent controls that dynamically adjust coolant temperature, flow, and pressure for precise chip cooling.

Remote management protocols supported include Redfish, SNMP, TCP/IP, and Modbus, as well as direct local management via a 10-inch touchscreen interface. CoolIT offers worldwide ordering, comprehensive support, and onsite services in over 75 countries including system design, installation, CDU-to-server certification, and maintenance.

“CoolIT engineered the CHx1500 to exceed AI and HPC’s most demanding cooling roadmap requirements,” said Neil Mulji, CoolIT’s VP, Product. “What we created in the CHx1500 is not only the most powerful row-based CDU unit in the market – providing the best cost per kW – but also a unit packed with all the advanced features and functionality that our OEM and hyperscale customers expect of CoolIT.”

Source: CoolIT Systems

Chroma — below posts

Get Data Center Engineering News In Your Inbox:

By subscribing, you agree to our Privacy Policy and Terms of Use. You can unsubscribe at any time.

Chroma — tower

Popular Posts:

Johnson-Controls-has-launched-an-Absorption-Chiller-Reference-Design-Guide-aimed-at-data-centers-running-on-on-site-power-generation
Johnson Controls' new absorption chiller guide targets 44% lower cooling power in AI data centers
trm-DC4-landing-page-banner
CPC says its full-flow AI cooling connectors cut pressure drop up to 90%
39D1CAB6-7D1C-4CA7-A2CF-D0919F6EA523_1_105_c
EdgeSites uses existing buildings to deploy 1 MW immersion-cooled AI compute
Why data center power validation is moving to real-time simulation
Why data center power validation is moving to real-time simulation
image-schneider-electric-and-amd-release-first-helios-platfo
AMD Helios reference design targets 246 kW racks, 10.4 MW AI clusters

Share Your Data Center Engineering News

Do you have a new product announcement, webinar, whitepaper, or article topic? 

TDK — tower ()

Get Data Center Engineering News In Your Inbox:

By subscribing, you agree to our Privacy Policy and Terms of Use. You can unsubscribe at any time.

TDK — leaderboard ()