Chroma — leaderboard

Rosenberg introduces high-efficiency 575 Volt EC fan module optimized for data center cooling

Rosenberg USA has introduced a new high-performance EC fan module, the Model N88-50709, featuring a robust 575 Volt, 7.4 kW electronically commutated (EC) motor paired with its I-Series backward-curved impeller, winner of a 2025 AHR Innovation Award. Designed for high-volume airflow applications, this unit delivers airflow up to 8,000 CFM at 5 inWG static pressure with a noise output of only 88 dB(A). At free air (no back pressure), the module achieves a maximum airflow of approximately 12,000 CFM.

The N88-50709 incorporates Rosenberg’s Gen 3+ EC motor technology, which maintains consistently high efficiency across a range of operating speeds and conditions, including partial-load scenarios. The motor accepts input voltages from 460 to 600V AC, and fan speed is infinitely adjustable, allowing precise airflow control.

The award-winning I-Series impeller design integrates five aluminum backward-curved, hollow-profile airfoil section blades and an efficiency-enhancing circumferential diffuser. According to Rosenberg USA, compared to previous generation impellers, the new design boosts efficiency by up to 11% and reduces noise by more than half, depending on fan size and operating point.

With low installation depth and maintenance-free operation due to a cool-running EC motor and permanently lubricated ball bearings, the Model N88-50709 is engineered for simple integration into data center cooling systems, as well as industrial HVAC and commercial refrigeration equipment.

Rosenberg fans are also utilized throughout critical infrastructure, including air cooling aids for variable frequency drives, wind power generators, power converters, solar inverters, uninterruptible power supplies, telecom racks, and in applications spanning railway, marine, military, and avionics environments.

Source: Rosenberg USA

Chroma — below posts

Get Data Center Engineering News In Your Inbox:

By subscribing, you agree to our Privacy Policy and Terms of Use. You can unsubscribe at any time.

Chroma — tower

Popular Posts:

Starline
Design instability: when the build takes longer than the spec lasts
Quantumscape
Batteries in the AI factory: from spare tire to shock absorber
2602-Southwire-EnergizingTheDigitalEra-eGuide-HIGHRES-5
How to reduce electrical infrastructure risk in data center projects: download the guide
CPC-TRM-Tech-Guide-Liquid-Cooling-Reliability-(1)-4
In liquid cooling reliability, tubing choice creates another layer of protection
Why static load models fail at hyperscale data center interconnection
Why static load models fail at hyperscale data center interconnection

Share Your Data Center Engineering News

Do you have a new product announcement, webinar, whitepaper, or article topic? 

TDK — tower ()

Get Data Center Engineering News In Your Inbox:

By subscribing, you agree to our Privacy Policy and Terms of Use. You can unsubscribe at any time.

TDK — leaderboard ()