DCX 8 MW CDU adds continuous coolant chemistry monitoring and dosing

DCX Liquid Cooling Systems has added coolant chemistry monitoring and automated treatment to its Facility Distribution Unit (FDU) product family, targeting hall-scale liquid-cooling loops used in high-density AI deployments. The company puts the coolant quality controls inside the same frame as the pumps and controls, aiming to keep coolant loops within specification between scheduled service visits.

The FDU continuously monitors coolant conditions and automatically corrects chemistry drift using integrated electronic dosing pumps. DCX lists eight coolant parameters under continuous monitoring and says the dosing system can supply inhibitors, biocides, and pH control additives to maintain loop conditions without waiting for lab results and follow-up corrective actions.

For operators running MW-class CDUs that serve an entire AI data hall, coolant management shifts from routine maintenance to an availability risk: chemistry drift can reduce thermal performance over time and accelerate corrosion or biofouling if it goes undetected. Building monitoring and dosing directly into the distribution unit is a practical move because it shortens detection-to-correction time and reduces dependence on periodic sampling workflows.

DCX says inline sensors measure turbidity, conductivity, pH, glycol concentration, and corrosion rate. Three automatic dosing channels deliver inhibitor, pH additive, and biocide, with dosing events counted and logged. The controller holds pH at a set point and treats fresh make-up fluid in proportion to its volume. Operators interact with the system through the FDU touchscreen, including a status view and a live diagram of both cooling loops with pumps, valves, and dosing lines. The system supports both PG25 and deionized-water loops.

On the thermal and hydraulic side, DCX rates the FDU family for up to 8 MW of heat transfer capacity at a 2 °C approach temperature and 45 °C supply (ASHRAE W45/W+). Maximum flow is listed at 3000 GPM (11,000 LPM). The unit uses four pumps and supports either N+N or N+1 configurations.

“At this scale, the coolant is as critical as the pumps,” said Maciek Szadkowski, CTO of DCX Liquid Cooling Systems. “With this new feature, we resolve the most challenging risk in liquid cooling-long-term quality assurance of the cooling medium.”

DCX says built-in coolant quality control and treatment is standard across the FDU family and is available immediately for hyperscale and high-density AI projects.

DCX Liquid Cooling Systems

Source: DCX Liquid Cooling Systems

Yokogawa — below-posts ()

Get Data Center Engineering News In Your Inbox:

By subscribing, you agree to our Privacy Policy and Terms of Use. You can unsubscribe at any time.

Sponsored: Infineon at OCP 2026: Exclusive Content Hub. Executive interviews, technical documents, reference designs, and live expert panel. Unlock the hub.
Chroma — tower

Popular Posts:

Engineering AI Rack Power: Infineon Answers the Questions Asked at OCP, live expert panel with Carl Smith, Davide Chiola and Michael Williams
AI data center architecture evolution and key findings from OCP
thumb-dc1-selection-guide
Data center semiconductor selection guide
algm-data-center-news-release-image-202610
Allegro adds 800V data center current sensors and 48V cooling fan driver
thumb-sst1-solid-state-transformers
Why line-frequency transformers fall short in AI data center power design
aggreko-tier-4f-canada
Aggreko launches Tier 4 Final generators for Canada, including 600V 1200 kW model

Share Your Data Center Engineering News

Do you have a new product announcement, webinar, whitepaper, or article topic? 

Yokogawa — tower ()

Get Data Center Engineering News In Your Inbox:

By subscribing, you agree to our Privacy Policy and Terms of Use. You can unsubscribe at any time.

Chroma — leaderboard